15 Kilowatts Hober MPPT Solar Water Pumping Inverter
KSh150,000.00 Ex-VAT
- Convert the DC power of the solar array into AC power to the water pump. Soft start and Variable Frequency drive the pump.
- Second Generation of MPPT Function: Automatic /don’t need to set MPPT voltage by LCD/LED. Efficiency is Max to 30% higher than the inverter which needs to set the MPPT Voltage, more output water flow.
- One key for startup/Stop, support is to adjust the output water flow.
- Without battery, storing water is more efficient than storing electricity, and reduces the cost of construction, operating, and routine maintenance
15 Kilowatts Hober MPPT Solar Water Pumping Inverter
KSh150,000.00 Ex-VATRequest a Call Back
- Ask a Question
15 Kilowatts Hober MPPT Solar Water Pumping Inverter
KSh150,000.00 Ex-VATAsk a Question
... people are viewing this right now
15 Kilowatts Hober MPPT Solar Water Pumping Inverter
Hober 15Kw Three Phase Solar Pumping Inverter converts the DC power of the PV array to Three Phase-AC power and drives the pump, according to the power of PV array output, regulates output frequency, and lets PV output max power at all times.
Hober Hybrid Solar Water Pumping Inverter Brand Introduction
Hober 15Kw Three-Phase Hybrid Solar Pumping Inverter Advantage:
- Hybrid (Solar, AC Power, Battery, Diesel generator)
- Automatic switching
- MPPT MEPT function
- Solar Booster for saving solar panels
- Metal Shell, Waterproof IP65
- Setting working time, Controlling the flow
- Film capacitor 100000 working hours
- Work with three-phase 380V/415V pumps that meet its output parameters.
- Has accessible sensor connectors for both the tank and borehole.
- Unique High PV Voltage support of up to 900V, unlike most other brands in the market.
Product Features
- Convert the DC power of the solar array into AC power to the water pump. Soft start and Variable Frequency drive the pump.
- Second Generation of MPPT Function: Automatic /don’t need to set MPPT voltage by LCD/LED. Efficiency is Max to 30% higher than the inverter which needs to set the MPPT Voltage, more output water flow.
- One key for startup/Stop, support is to adjust the output water flow.
- Without battery, storing water is more efficient than storing electricity, and reduces the cost of construction, operating, and routine maintenance
- Protection: Over temperature, over input voltage, over input current, overrated load, input anti-reverse output short circuit, phase missing, phase unbalance, lighting, dry run protection by software/Well sensor, waterproof.
- water level detective of the tank for overflow, Optional pressure sensor for the long distance between the well and tank.
- Mobile phone control or computer remote monitoring through RS485/GPRS/wifi/Ethernet(optional)
Product ApplicationsÂ
- Residents living water
- Irrigation
- Desert control
- Solar powered Borehole water pumping
- Livestock watering
Product Specifications
Model
|
HSPH15KH
|
|
Solar Panel DC Input
|
Max Voc Voltage
|
900V
|
Min Vmp Voltage
|
400V
|
|
Recommend Vmp Voltage
|
≥500V (Only Solar), ≥560 V (Hybrid Power)
|
|
Max MPPT Efficiency
|
99%
|
|
Max Input Current
|
48 A
|
|
Number Of Strings
|
2
|
|
Overload Power
|
24KW
|
|
Note
|
Automatic MPPT Function to Identify the Voc and Vmp of Solar Panel, without programming
|
|
Hybrid AC/Generator Input
|
Voltage
|
3 Phase 380/400/440V
|
Max Input Current
|
36 A
|
|
Hybrid Mode
|
Automatic.AC supplement automatic while solar is in low power mode and AC disconnect automatic while solar power recovery
|
|
AC Output (For Pump, Rerator, Fan Parameters)
|
Max Adapted AC Pump Horse Power
|
20 HP
|
Max Adapted AC Pump Power
|
15KW
|
|
Drive Mode
|
3Phase Variable Frequency Drive
|
|
Max Output voltage
|
380/400/440V
|
|
Max Output frequency
|
50 ~ 60 Hz (support program range 15 to 60Hz)
|
|
Max Output Current
|
48 A
|
|
Max Efficiency
|
97%
|
|
Water Level Sensor(Borehole / Tank)
|
Yes
|
|
GPRS SMS Monitor&Controller
|
YES(Optional)
|
|
Support Remote Monitoring & Control System (SPMCS)
|
YES(Optional)
|
|
Display
|
LCD display
|
|
Waterproof
|
IP65
|
|
Noise
|
< 50dB
|
|
Cooling Method
|
Force Cooling by Fan (IP68)
|
|
Operating Environment
|
Operating Environment Temperature
|
-10 to 60℃, Above 60℃ need to derate load
|
Max Humidity
|
95%RH
|
|
Using Altitude
|
< 3000m, Above 3000m need to derate load
|
|
Others
|
Prohibiting the installation location: direct sunlight, thick dust, corrosive gas or oil mist, flammable gas, liquid. etc
|
|
Package
|
Size
|
550*350*285 MM
|
Weight
|
15.5 KG
|
Based on 0 reviews
0.00
Overall
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
|
|
0% |
Be the first to review “15 Kilowatts Hober MPPT Solar Water Pumping Inverter” Cancel reply
brand:
Related Products
Victron MultiPlus 24V-3000VA-35A-50-230V Inverter-Charger
KSh161,000.00 Ex-VAT
Add to cart
- Input Battery Voltage Range: 38-66V
- Nominal AC Output Voltage: 230VAC
- Continuous Power Rating: 5000VA
- Peak Inverter Efficiency: 95%
- Nominal DC Input Voltage: 48V
- Frequency Range AC Input: 45-65Hz
- Dimensions: 444x328x240mm
- Weight: 30kg
Victron Multiplus 48-5000-70 5000W Inverter-Charger
KSh280,000.00 Ex-VAT
Add to cart
- Input Battery Voltage Range: 38-66V
- Nominal AC Output Voltage: 230VAC
- Continuous Power Rating: 5000VA
- Peak Inverter Efficiency: 95%
- Nominal DC Input Voltage: 48V
- Frequency Range AC Input: 45-65Hz
- Dimensions: 444x328x240mm
- Weight: 30kg
GIANDEL Power Inverter Pure Sine Wave 600Watt
KSh6,800.00 Ex-VAT
Add to cart
- Power (2 AC Outlets): 600W Rated,1200W peak
- Max Efficiency 90%
- THD ≤3%
- USB output: 1xDC 5V/2.1A(max)
- Output wave form: Pure sine wave
- Nominal input voltage:12V(9.8-16VDC)
- Nominal output voltage: 110-120VAC
- Internal fuses:30A
- Battery cables(9AWG): one pair with a length of 2 ft.
- Remote controller: remote controller with 15ft cable. More convenient to control the inverter ON/OFF
- No load current:0.7A
Scott Power 7.5KVA Solar Power Conditioning Unit (PCU)
KSh138,500.00 Ex-VAT
Add to cart
- Model 2KVA/2.5KVA/3.5KVA/5KVA/7.5KVA/10KVA/12KVA/15KVA
- AC Mains Mode
- Input Voltage Range (Eco Mode) 100 to 280 VAC ± 5 VAC (Wide Range)
- Input Voltage Range (Inv. Mode) 180 to 260 VAC ± VAC
- Changeover Time Maximum < 30 ms (in Eco Mode) and < 10 ms (in Inv. Mode)
- Charging Current (NC) 5A± 1A
- Charging Current (HC) 22A ± 1A
- Boost Charging Voltage 14.4 ± 0.2 VDC per Batt.
- Float Charging Voltage 14.4 ± 0.2 VDC per Batt.
Victron Multiplus Multi 1200w-12V and 24V Pure Sinewave Inverter Charger
KSh100,000.00 Ex-VAT
Add to cart
- Input Battery Voltage Range: 9.5 – 17 V
- Nominal AC Output Voltage: 230 VAC ± 2%
- Continuous Power Rating: 1200VA @ 25 °C
- Peak Inverter Efficiency: 93%
- Waveform: Pure Sine Wave
- Nominal DC Input Voltage: 12V
- Nominal AC Input Voltage/Frequency: 187-265 VAC, 45 – 55 Hz
- Dimensions: 375x214x110mm
- Weight: 10kg
victron quattro 15000 watts 48v inverter charger
KSh650,000.00 Ex-VAT
Add to cart
- Multifunctional, with intelligent power management
- Two AC inputs and two AC outputs
- Three phase capability
- Split phase options
- PowerControl – Dealing with limited generator, shore side or grid power
- Unique PowerAssist – Boosting the capacity of shore or generator power
- Input Voltage range: 38 to 66 Volt DC
- Output voltage: 230 Volts AC +/-2% @ 50 Hz
Pure Sine Wave Livguard Solar Inverter,220,Model Name:4.0KVA MPPT
KSh46,700.00 Ex-VAT
Add to cart
- Brand: Livguard
- Model Name: 4.0kva MPPT
- Capacity: 4000w
- Waveform: Pure Sine Wave
- Output Voltage: 220
Victron Multiplus 24V-5000-70 5000W Inverter-Charger
KSh290,000.00 Ex-VAT
Add to cart
- Input Battery Voltage Range: 38-66V
- Nominal AC Output Voltage: 230VAC
- Continuous Power Rating: 5000VA
- Peak Inverter Efficiency: 95%
- Nominal DC Input Voltage: 48V
- Frequency Range AC Input: 45-65Hz
- Dimensions: 444x328x240mm
- Weight: 30kg
Scott Power 10KVA Solar Power Conditioning Unit (PCU)
KSh193,500.00 Ex-VAT
Add to cart
- Model 2KVA/2.5KVA/3.5KVA/5KVA/7.5KVA/10KVA/12KVA/15KVA
- AC Mains Mode
- Input Voltage Range (Eco Mode) 100 to 280 VAC ± 5 VAC (Wide Range)
- Input Voltage Range (Inv. Mode) 180 to 260 VAC ± VAC
- Changeover Time Maximum < 30 ms (in Eco Mode) and < 10 ms (in Inv. Mode)
- Charging Current (NC) 5A± 1A
- Charging Current (HC) 22A ± 1
- Boost Charging Voltage 14.4 ± 0.2 VDC per Batt.
- Float Charging Voltage 14.4 ± 0.2 VDC per Batt.
Growatt MOD 10KTL3 -X 10Kw Grid-Tie Three-Phase Solar Inverter
KSh156,000.00 Ex-VAT
Add to cart
- Model: MOD 10KTL3-X | MOD 11KTL3-X | MOD 12KTL3-X | MOD 13KTL3-X | MOD 15KTL3-X
- recommended PV power: 15000W | 16500W | 18000W | 19500W | 22500W
- DC voltage: 1100V
- Start Voltage: 200V
- Nominal voltage: 580V
- of MPP trackers: 2
- AC nominal power: 10000W | 11000W | 12000W | 13000W | 15000W
- Nominal AC voltage: 220V/380V, 230V/400V (340-440V) | 50/60 Hz (45-55Hz/55-65 Hz)
Reviews
There are no reviews yet.